12
1 SERVO PARAMETER DETAILS
1.2 Basic setting servo parameters group ([Pr. PA_ _ ])
1.2
Basic setting servo parameters group ([Pr. PA_ _ ])
[Pr. PA01_Operation mode (**STY)]
[Pr. PA01.1_Operation mode selection]
0: Standard control mode
4: Linear servo motor control mode
The setting value "4" can be used on servo amplifiers with firmware version B2 or later.
[Pr. PA02_Regenerative option (**REG)]
[Pr. PA02.0-1_Regenerative option selection]
Select a regenerative option.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 037 Parameter error] occurs.
00: Regenerative option is not used.
• No regenerative resistors are used on servo amplifiers with a capacity of 100 W/200 W.
• Built-in regenerative resistors are used on servo amplifiers with a capacity of 0.4 kW to 3.0 kW.
02: MR-RB032
03: MR-RB12
05: MR-RB30
06: MR-RB50 (A cooling fan is required.)
0D: MR-RB14
0E: MR-RB34
[Pr. PA03_Absolute position detection system (*ABS)]
[Pr. PA03.0_Absolute position detection system selection]
Set this servo parameter when using the absolute position detection system. If the absolute position detection system is
switched to the incremental system, the home position is erased. Execute homing again when the absolute position detection
system is enabled.
0: Disabled (incremental system)
1: Enabled (absolute position detection system)
In the following case, enabling the absolute position detection system triggers [AL. 037 Parameter error].
• When an incremental type encoder is being used
Initial value
Setting range
Ver.
00003000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
00h
Refer to the text
A4
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Содержание MELSERVO MR-JET-G Series
Страница 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Страница 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Страница 163: ......