1 SERVO PARAMETER DETAILS
1.2 Basic setting servo parameters group ([Pr. PA_ _ ])
23
1
[Pr. PA22_Position control configuration selection (**PCS)]
[Pr. PA22.1_Super trace function selection]
0: Disabled
2: Enabled
[Pr. PA23_Drive recorder desired alarm trigger setting (DRAT)]
This servo parameter is enabled in the following conditions:
• [Pr. PF80.0 Drive recorder - Operation mode selection] = "0" (automatic setting mode)
• [Pr. PF80.0] = "1" (manual setting mode) and [Pr. PF82.0 Drive recorder - Trigger mode selection] = "0" (alarm trigger)
Ex.
To activate the drive recorder when [AL. 050 Overload 1] occurs, set "00005000h".
To activate the drive recorder when [AL. 050.3 Thermal overload error 4 during operation] occurs, set this servo parameter to
"00005003h".
[Pr. PA23.0-1_Alarm detail number setting]
Set this to execute the trigger with a desired alarm detail No. for the drive recorder function.
When "00h" is selected, only the desired alarm No. setting will be enabled.
[Pr. PA23.2-4_Alarm number setting]
Set this to execute the trigger with a desired alarm No. for the drive recorder function.
When "000h" is selected, the desired alarm trigger of the drive recorder is disabled.
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A4
Initial value
Setting range
Ver.
00000000h
Refer to the relevant detail No.
Refer to the relevant detail No.
Initial value
Setting range
Ver.
00h
00h to FFh
A4
Initial value
Setting range
Ver.
000h
000h to FFFh
A4
Содержание MELSERVO MR-JET-G Series
Страница 1: ...MR JET G User s Manual Parameters MR JET _G MR JET _G N1 Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 148: ...146 4 SERVO PARAMETER SETTING METHOD 4 2 Object dictionary MEMO ...
Страница 159: ...6 NETWORK PARAMETER SETTING METHOD 6 1 Engineering tool 157 6 MEMO ...
Страница 163: ......