MELSEC-WS
Procedures before operation
97
The following table shows an example of the execution result of the program for
writing output data sets in polling mode.
Device
Storage value
(hex)
Byte
swapping
*1
Description
D900 000A
H
Not required
Receive data length
D901 0004
H
Required
Response command
D902 0000
H
Status
0:
Successful
1:
Error
*1 Since the QJ71E71-100 treats application data in Little Endian format, the byte-order needs to be
swapped.
(3) Monitoring data with Setting and Monitoring Tool
The written output data sets can be monitored in the
Ethernet to CPU
dialog of
Setting and Monitoring Tool. The following window shows the execution result of
the program for writing output data set in polling mode.
Table 32:
Execution result
example in polling
mode (output data set
writing)
Figure 55:
Monitoring result in the
Ethernet to CPU dialog