3Installation of optional equipment
Replacement procedure for machine cables (replaceable type)
3-45
Do not cut cable ties other than the cable tie <1>.
Also, be careful not to cut the cables when cutting the cable tie.
3) Remove the 1M connector <2> and CN1 connector <3>.
4) Remove the FG wire <4> of the motor signal cable. Remove the installation screw (b) used to fix the
FG wire terminal.
5) Remove the CN21 connector <5>.
The origin data will be erased if you remove a connector other than the CN21
connector <5>.
Refer to
Page 68, "5.6 Resetting the origin"
and set the origin again.
6) Remove the installation screws (c) from the CN plate.
7) Confirm that <1> to <5> are all removed, and pull the connector out from the rectangular hole on CON
plate B, and remove the machine cables together with the CN plate.
Follow the removal procedure from
to
in reverse to install the optional machine cables (replaceable
type).
When installing the CON plate B and the CN plate, use a bolting torque of 1.39 to 1.89 N·m for the
installation screws.
When installing CON plate B and the CN plate, ensure that the cables are not
pinched by the plates.
This completes replacement of the machine cables (replaceable type).
CAUTION
CAUTION
CAUTION