![Mitsubishi Electric MELFA RH-3CRH Series Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/mitsubishi-electric/melfa-rh-3crh-series/melfa-rh-3crh-series_instruction-manual_240807056.webp)
3-44
Replacement procedure for machine cables (replaceable type)
3Installation of optional equipment
3.2 Replacement procedure for machine cables (replaceable type)
The replacement method for optional machine cables (replaceable type) is explained.
The robot arm comes with standard accessory machine cables installed before shipment.
Fig.3-2:Replacement method for machine cables (replaceable type)
1) Remove the installation screws (a) from CON plate B on the back of the base, and pull CON plate B
forward.
When pulling out CON plate B, ensure the exposed circuit board does not come
into contact with any surrounding metal parts.
2) Cut the cable tie <1> with nippers, and remove the cables from the plate. The cables use the two
holes on the plate and are fixed with cable ties.
㻮
㻭
Machine cables
CON plate B
Base section
(a) Hexagon socket bolt
M4×12 (6 places)
(b) Hexagon socket
bolt
<4> FG wire (yellow and green)
CON plate B
<1> Cable tie
<2> 1M connector
<3> CN1
connector
Base section
<4> FG wire (yellow and green)
Motor signal
cable
<5> CN21 connector
CN plate
(c) Hexagon socket
bolt
View A
View B
Internal circuit board
* Ensure the exposed circuit board
does not come into contact with
any surrounding metal parts.
CAUTION