9. Adjustment
9 - 12
The recommended setting value of depth for each setting frequency is shown in the table below.
Setting frequency and recommended setting value of depth for machine resonance suppression filter 1,2
Setting frequency
Recommended
setting value
Depth Setting
frequency
Recommended
setting value
Depth
2250Hz 0 -
∞
281Hz 4 -12.0
1500Hz 0 -
∞
264Hz 4 -12.0
1125Hz 0 -
∞
250Hz 8 -6.0
900Hz 0 -
∞
225Hz 8 -6.0
750Hz 0 -
∞
204Hz 8 -6.0
642Hz 0 -
∞
187Hz 8 -6.0
562Hz 0 -
∞
173Hz 8 -6.0
500Hz 0 -
∞
160Hz 8 -6.0
450Hz 0 -
∞
150Hz 8 -6.0
409Hz 0 -
∞
140Hz C -2.5
375Hz 4 -12.0
128Hz C -2.5
346Hz 4 -12.0
112Hz C -2.5
321Hz 4 -12.0
100Hz C -2.5
300Hz
4
-12.0
(Note1)
The setting of the standard depth compensation in the above table indicates the HEX setting value applied when the setting
of “bit 0” or “bit 4” is “0”.
(Note2)
The recommended setting value in the above table is a guideline. According to the machine characteristic, the depth must
be changed in some cases.