Appendix 3. Compliance with European EC Directives
A3 - 4
(6) Peripheral
devices
[1] Use EN/IEC Standards compliant parts for the circuit breaker and contactor.
[2] Select circuit breaker with instantaneous trip function. (Trip within 30 second when over
current of 600%). Apply Annex C of EN60204-1 for sizing of the circuit breaker.
(7) Miscellaneous
[1] Refer to the next section "EMC Installation Guidelines" for methods on complying with the
EMC Directives.
[2] Ground the facility according to each country's requirements.
[3] The control circuit connector (
{
) is safely separated from the main circuit (
).
[4] Inspect the appearance before installing the unit. Carry out a performance inspection of the
final unit, and save the inspection records.
P
Mitsubishi
CNC
SV1, 2
(CSH21)
24V power
T
S
R
Contactor
Regenerative
resistor unit
Ground
: Main circuit
: Control circuit
CN1A
CN1A
CN4
CN9
CN22
CN4
CN9
CN22
L1
L2
L3
C
CN30
CN31L
CN2L
CN1B
CN1B
LU
LV
LW
LU
LV
LW
CN2M
CN2L
MU
MV
MW
CN31M
CN31L
Motor side
detector
Motor side
detector
MDS-A-BT-
MDS-R-V2-
MDS-R-V1-
Motor side
detector
Motor
Motor
Motor
Regenerative
resistor unit
No-fuse
breaker
Machine side
detector
CN3L
Machine side detector
CN3L
Machine side detector
CN3M
Contactor
No-fuse
breaker
T
S
R
Содержание MELDAS MDS-R Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 76: ......
Страница 197: ...11 1 11 Characteristics 11 1 Inspections 11 2 11 2 Service parts 11 2 ...
Страница 226: ......
Страница 242: ......
Страница 266: ......
Страница 274: ......
Страница 280: ......
Страница 282: ......
Страница 285: ......