8. Setup
8 - 5
(2) Electronic gear related parameters
The setting range of the following parameters, which configure the electronic gears, may be limited
according to the combination.
Setting electronic gear related parameters
No. Abbrev. Parameter
name
Explanation
Setting
range (Unit)
SV001 PC1*
Motor side gear
ratio
1 to 32767
SV002 PC2*
Machine side gear
ratio
Set the motor side and machine side gear ratio.
For the rotary axis, set the total deceleration (acceleration) ratio.
Even if the gear ratio is within the setting range, the electronic gears may
overflow and causes initial parameter error (servo alarm No. 37).
1 to 32767
SV018
PIT* Ball screw pitch
Set the ball screw pitch. Set to "360" for the rotary axis.
1 to 32767
(mm/rev)
In the case of the semi-closed loop control
Set the same value as SV020 (RNG2).
(Refer to the explanation of SV020.)
1 to 9999
(kp/rev)
In the case of the full-closed loop control
This is available for the relative position oblong wave output specification
linear scale.
Set the number of pulses per ball screw pitch.
Detector model
name
Resolution SV019
setting
Relative position oblong
wave output scale
Refer to detector
specification manual.
SV018 (PIT)(mm)/
Resolution (µm)
SV019 RNG1*
Position detector
resolution
1 to 9999
(kp/PIT)
Set the number of pulses per one revolution of the motor side detector.
Detector model name
Motor type
SV020 setting
OSA104S2 HF
□□
-A42 100
OSA17 HF
□□
-A47 100
SV020 RNG2*
Speed detector
resolution
1 to 9999
(kp/rev)
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.
(3) Detector type related parameters
(a) For semi-closed loop control
Set the following parameter as below when controlling by using only detector of motor.
Setting for semi-closed loop control
No. Abbrev. Parameter
name
Explanation
bit
Explanation
8
Set the detector type.
9
Set the position detector type for "pen", and the speed detector type
for "ent".
A
ent
In the case of the semi-closed loop control, set the same value for
"pen" and "ent".
B
Detector model name
pen setting ent setting
C
OSA104S2, OSA17
2
2
D
E
pen
F
SV025 MTYP* Motor/detector
type
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power turned ON again.
Содержание MELDAS MDS-R Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 76: ......
Страница 197: ...11 1 11 Characteristics 11 1 Inspections 11 2 11 2 Service parts 11 2 ...
Страница 226: ......
Страница 242: ......
Страница 266: ......
Страница 274: ......
Страница 280: ......
Страница 282: ......
Страница 285: ......