2. Specifications
2 - 16
2-2 Servo drive unit
2-2-1 Installation environment conditions
Common installation environment conditions for servo drive unit are shown below.
Ambient temperature
Operation: 0 to 55°C (with no freezing), Storage / Transportation: -15°C to 65°C (with no freezing)
Ambient humidity
Operation: 90%RH or less (with no dew condensation)
Storage / Transportation: 90%RH or less (with no dew condensation)
Atmosphere
Indoors (no direct sunlight)
With no corrosive gas, inflammable gas, oil mist, dust or conductive fine particles
Altitude Operation/Storage:
1000
meters or less above sea level, Transportation: 10000 meters or less above sea level
Environ-
ment
Vibration/impact 5.9m/s
2
(0.6G)
2-2-2 Specifications list
(1) 1-axis servo drive unit
1-axis servo drive unit MDS-R-V1 Series
Servo drive
unit type
MDS-R-V1-
20 40 60 80
Nominal maximum current
(peak)
[A]
20 40 60 80
Power facility capacity
[kVA]
1.3 1.9 4.0 5.8
Rated voltage
[V]
155AC
Output
Rated current
[A]
3.8 6.6 12.0
17.0
Rated voltage
[V]
3-phase 200 to 230AC
Input
Rated current
[A]
3.0 6.0 11.0
15.0
Voltage [V]
24DC
±
10%
Current
[A]
Max. 0.6
Max. 0.8
Rush current
[A]
2.4
3.2
Control
power
Rush
conductivity
time
[ms]
100ms
Earth leakage current
[mA]
1 (Max. 2)
Control method
Sine wave PWM control method Current control method
Braking
Regenerative resistor
External option
Dynamic
brakes
Built-in
External analog output
0 to +5V, 2ch (data for various adjustments)
Structure
Protection type (Protection method: IP10)
Cooling method
Forced wind cooling (Fin)
Weight [kg]
3.3 3.3 5.0 5.0
Heat radiated at rated
output
[W] 46
73
101
141
Noise
Less than 55dB
(2) 2-axis servo drive unit
2-axis servo drive unit MDS-R-V2 Series
Servo drive
unit type
MDS-R-V2-
2020 4020 4040
6040 6060 8040 8060 8080
Nominal maximum current
(peak)
[A] 20/20 40/20 40/40 60/40 60/60 80/40 80/60 80/80
Power facility capacity [kVA]
2.5
3.2
3.9
5.9 8.0 7.8 9.8
11.7
Rated voltage
[V]
155AC
Output
Rated current
[A]
3.8 + 3.8
6.6 + 3.8
6.6 + 6.6
12.0 + 6.6
12.0 + 12.0
17.0 + 6.6
17.0 + 12.0
17.0 + 17.0
Rated voltage
[V]
3-phase 200 to 230AC
Input
Rated current
[A]
6.0
9.0
12.0 17.0 22.0
21.0 26.0 30.0
Voltage [V]
24DC
±
10%
Current
[A]
Max. 0.9
Max. 1.1
Max. 1.5
Rush current
[A]
3.6
4.4
6.0
Control
power
Rush
conductivity
time
[ms] 100ms
Earth leakage current
[mA]
1 (Max.4 for 2 axes)
Control method
Sine wave PWM control method Current control method
Braking
Regenerative resistor
External option
Dynamic
brakes
Built-in
External analog output
0 to +5V, 2ch (data for various adjustments)
Structure
Protection type (Protection method: IP10)
Cooling method
Forced wind cooling (Fin)
Weight [kg]
3.5
3.5
3.5 5.5 5.5 5.5 5.5 5.5
Heat radiated at rated
output
[W]
89 115 143 170 200 218 240 278
Noise
Less than 55dB
Содержание MELDAS MDS-R Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 76: ......
Страница 197: ...11 1 11 Characteristics 11 1 Inspections 11 2 11 2 Service parts 11 2 ...
Страница 226: ......
Страница 242: ......
Страница 266: ......
Страница 274: ......
Страница 280: ......
Страница 282: ......
Страница 285: ......