The following shows a calculation example for considering heat radiation countermeasures.
<Control panel outline dimension (assumption) >
When installing four units which have the heating value in the panel of 15W
Top of panel inside Fan for agitating
600
300
600
Heat radiation area (A): When a bottom section contacts with a machine
A = 0.6 x 0.3 + 0.6 x 0.6 x 2 + 0.6 x 0.3 x 2 = 1.26 (m
2
)
(Top face) (Front/back face) (Side face)
*Actually, sections contacting other objects are excluded.
Heating value in panel (W): when installing four units which are 15W
W = 15 x 4 = 60 (W)
<Considering nec
essity of agitating f
an>
1 Temperature standard
(1) Standard of temperature in panel (around each unit)
T
≤
55°C
(2) External peripheral temperature
Ta = 0 to 45°C
(3) Internal temperature rise value
∆
T = T - Ta(MAX) = 10°C
2 C
ooling
capacity of control panel (W1)
W1 = U x A x
∆
T
∆
T = Internal temperature rise value (=10°C)
U = 6W/m
2
•
°C (with internal agitating fan)
4W/m
2
•
°C (without internal agitating fan)
A = Effective heat radiation area (m
2
)
(1) With internal agitating fan W1 = 6 x 1.26 x 10 = 75.6 (W) > 60 (W)
(2) Without internal agitating fan W1 = 4 x 1.26 x 10 = 50.4 (W) < 60 (W)
POINT
Measure an actual internal temperature, and install a fan or heat exchanger
which agitates the heat at the top of the unit if the temperature rise exceeds
10°C.
Internal fan is
required.
Содержание MELDAS MDS-R Series
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 76: ......
Страница 197: ...11 1 11 Characteristics 11 1 Inspections 11 2 11 2 Service parts 11 2 ...
Страница 226: ......
Страница 242: ......
Страница 266: ......
Страница 274: ......
Страница 280: ......
Страница 282: ......
Страница 285: ......