© Mitsubishi Electric Corporation
【
Remark
】
1) When changing CameraLinkClock_Select, this is
reflected including slave channel.
2) Because “Output Mode Setting” interacts with Line
Frequency and number of output pixel, please set this
setting based on your calculation for each setting.
3) Set to 28 if inputting invalid parameter data
(more than 28).
5-2-7 Output Mode Setting
[Function]
Switch output clock frequency of Camera Link®
72
Address
Register name
R/W
Parameter
Data
Function
Initial
6008h
CameraLink
Clock_Select
R/W
0 to 28
Switch Camera Link® output clock frequency
Refer to below tables for relationship of parameter vs.
clock frequency.
28
Camera Link® is a trade mark registered by AIA
(
Automated Imaging Association).
Relationship of parameter data vs. clock frequency.
5-2 Setting
⑤
: Output Clock Frequency Setting
Parameter Data
Clock Frequency
(MHz)
Parameter Data
Clock Frequency
(MHz)
Parameter Data
Clock Frequency
(MHz)
0 (0x00)
48.0
11 (0x0B)
57.6
22 (0x16)
72.0
1 (0x01)
50.7
12 (0x0C)
58.3
23 (0x17)
76.0
2 (0x02)
51.0
13 (0x0D)
60.0
24 (0x18)
76.8
3 (0x03)
51.4
14 (0x0E)
61.7
25 (0x19)
78.0
4 (0x04)
52.0
15 (0x0F)
62.4
26 (0x1A)
80.0
5 (0x05)
52.8
16 (0x10)
64.0
27 (0x1B)
81.6
6 (0x06)
53.3
17 (0x11)
65.1
28 (0x1C)
84.0
7 (0x07)
54.0
18 (0x12)
66.0
8 (0x08)
54.9
19 (0x13)
67.2
9 (0x09)
56.0
20 (0x14)
68.0
10 (0x0A)
57.0
21 (0x15)
68.6
TM-XJ959A
Содержание KD Series
Страница 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Страница 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Страница 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Страница 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Страница 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...