© Mitsubishi Electric Corporation
5-2-17 γ correction function
[Function]
Change output linearity based on Look-up table
(γ correction table).
The initial setting is γ=1 (γ correction OFF).
[Factory setting at look-up table]
γ table : γ=2.2
[Remark]
1)γ correction selects or specifies a gradation of 256 steps
(8 bit length), that is one of 4 blocks that 1024 steps (10bit
length) are divided by 4.
2)For more details of γ correction, refer to the Function
Specification.
82
Address
Register name
R/W
Parameter
Data
Function
Initial
70E0h GammaCorrectionEnable
R/W
0 or 1
Set γ correction On/Off
0:OFF /1:ON
0
5-2 Setting
⑮
:
Gamma
Correction
TM-XJ959A
0
256
512
768
1024
Output
GMSH_01
Gamma Table Threshold
256
512
768
1024
Input
GMSH_02
GMSH_03
Zone0
Zone1
Zone2
Zone3
Zone0
0-128
gradations
0
8bit-SRAM
FFh-00h
9
8
7
6
5
4
3
2
1
0 LSB
0
Zone1
129-346
gradations
1
8bit-SRAM
FFh-00h
1
Zone2
347-640
gradations
0
8bit-SRAM
FFh-00h
1
Zone3
641-1023
gradations
1
8bit-SRAM
FFh-00h
Gamma Curve
Data after
Conversion
Содержание KD Series
Страница 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Страница 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Страница 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Страница 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Страница 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...