4-3-1 Communication control block diagram
【
Line sync signal
】
1.
External sync. mode
External sync signal, input through communication port, is distributed
to the other block inside CIS. The line data from each block is
synchronized at line scan basis.
2.
Internal sync. mode
Sync signal created inside CIS is distributed to the other block inside
CIS. The line data from each block is synchronized at line scan basis.
【
Remarks
】
1) CIS can be controlled only through Master communication port.
(Signal through the other ports will not be reflected to CIS)
2) Confirm where to be connected from your Grabber board.
【
Communication control
】
L4 and L5 types
have two signal blocks for
Camera Link® , and the 1
st
signal block
(Connector D1 to D4) is the Master block. Main
functions of the CIS can be controlled through the
D1 of Master block. Slave block is used only for
receiving picture data.
In case of using of the external sync mode,
input trigger signal to the 1
st
Master
communication port (D1). (No input required for
the internal sync. mode.)
L6 type
have three signal blocks for Camera
Link® , and the 2
nd
signal block (Connector D5 to
D9) is the Master block. Main functions of the CIS
can be controlled through the D5 of Master block.
Slave block is used only for receiving picture data.
In case of using of the external sync mode,
input trigger signal to the 2nd Master
communication port (D5). (No input required for
the internal sync. mode.)
4-3 Communication control (overview)
…
…
・・・
・・・
Camera Link® is a registered trademark of AIA (Automated Imaging Association).
TM-XJ959A
Signal
block 1
Signal
block 2
Signal
block 3
Содержание KD Series
Страница 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Страница 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Страница 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Страница 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Страница 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...