3-1-9 The View of fixing construction in front of CIS from bottom
When the CIS is installed to your equipment, to absorb
small deformation of CIS(for example, the bend of aluminum parts of CIS),
please make the through holes to fix between CIS and your equipment
in the bracket prepared by customer as slot.
The example to fix the CIS is shown in below figure.
Please make a slot of Y direction
(Transport direction)
Please keep adjustment
width 1mm or more.
Through hole(Slot)
Fasting to your system by screw.
45
Bracket prepared
by customer
3-1 Installation
X(Scanning Direction)
Y