© Mitsubishi Electric Corporation
5-2-18 Mono mode Setting
[Function]
Select and switch a type of output image data when output
format when you set Output format to be Mono mode.
Output data : Red , Green or Blue pixel output,
Luminance value output
Luminance value
=
77/256
×
R
+
150/256
×
G
+
29/256
×
B
[Remark]
When you select RGB color mode and set
“MonoModeSelect=1” (Luminance value), each of R, G,
and B pixels outputs becomes the above value, providing
monochrome image.
83
Address
Register name
R/W
Parameter
Data
Function
Initial
7110h MonoModeSelect
R/W
0 to 3
Select Mono mode
(This function can change the output of RGB color mode.)
Mono mode 0: Green pixel output, 1: Luminance value output
2:Red pixel output, 3:Blue pixel output
RGB color mode 0: Color output, 1: Luminance value output
2: prohibit selection, 3: prohibit selection
0
5-2 Setting
⑯
: Mono mode Setting
TM-XJ959A