© Mitsubishi Electric Corporation
【
Remark
】
1) When changing OutputCh_Select, this is reflected
including slave channel.
2)
Because “Setting Number of Output Channel”
interacts with Line Frequency and number of output pixel,
please set this setting based on your calculation for each
setting.
5-2-8 Setting Number of Output Channel
[Function]
Setting number of output channel (connector)
Also check p.32 and p.33 of this document to setting this
parameter.
(
1ch Output
)
Image data is outputted from max. 6 connectors
(D1,D2,D5,D6,D9,D10) ) if using Medium, Full, Deca Config.
Image data is outputted from max. 3 connectors(D1,D5,D9) if
using Base Config.
This output method is called “1ch output”. This method is the
standard output mode in ordinary operation and ex-factory
condition.
(
2ch Output
)
Image data is outputted from max. 12 connectors (D1-D12) if
using Medium, Full, Deca Config.
Image data is outputted from max .6 connectors
(D1,D3,D5,D7,D9,D11) if using Base Config.
Above output method is called “2ch output”.
73
Address
Register name
R/W
Parameter
Data
Function
Initial
6054h
OutputCh_Select R/W
0 to 1
Setting number of output channel
0: Output from Ch1 only (1Ch Output)
1: Output from Ch1 and Ch2 (2Ch Output)
0
Camera Link® is a trade mark registered by AIA
(
Automated Imaging Association).
5-2 Setting
⑥
: Setting Number of Output Channel
TM-XJ959A
Содержание KD Series
Страница 3: ... Mitsubishi Electric Corporation 3 Chapter 1 Notice TM XJ959A ...
Страница 17: ... Mitsubishi Electric Corporation 17 Chapter 2 Overview TM XJ959A ...
Страница 40: ... Mitsubishi Electric Corporation 40 Chapter 3 Installation TM XJ959A ...
Страница 59: ... Mitsubishi Electric Corporation 59 Chapter 4 How to control CIS TM XJ959A ...
Страница 64: ... Mitsubishi Electric Corporation 64 Chapter 5 Getting started TM XJ959A ...