4. CONNECTION OF SERVO AMPLIFIER AND SERVO MOTOR
4 - 6
(b) Electromagnetic brake cable wiring diagrams
1) When cable length is 10 m or less
MR-BKS1CBL_M-A1-L
MR-BKS1CBL_M-A2-L
MR-BKS1CBL_M-A1-H
MR-BKS1CBL_M-A2-H
(Note 1)
(Note 2)
(Note 2)
AWG 20
AWG 20
(Note 1)
B1
B2
Servo motor
10 m or less
U
B
AWG 20
AWG 20
B1
B2
Servo motor
U
B
MBR-A
(Electromagnetic
brake interlock
for A-axis)
CALM
(AND
malfunction)
MBR-B
(Electromagnetic
brake interlock
for B-axis)
(Note 4)
24 V DC power supply
for electromagnetic
brake
(Note 3)
(Note 1)
(Note 2)
AWG 20
AWG 20
B1
B2
Servo motor
U
B
MBR-C
(Electromagnetic
brake interlock
for C-axis)
(Note 5)
MR-BKS1CBL_M-A1-L
MR-BKS1CBL_M-A2-L
MR-BKS1CBL_M-A1-H
MR-BKS1CBL_M-A2-H
MR-BKS1CBL_M-A1-L
MR-BKS1CBL_M-A2-L
MR-BKS1CBL_M-A1-H
MR-BKS1CBL_M-A2-H
Note 1. Connect a surge absorber as close to the servo motor as possible.
2. There is no polarity in electromagnetic brake terminals (B1/B2).
3. Create the circuit in order to shut off by interlocking with the emergency stop switch.
4. Do not use the 24 V DC interface power supply for the electromagnetic brake.
5. This connection is for the MR-J4 3-axis servo amplifier.
When fabricating the electromagnetic brake cable MR-BKS1CBL_M-_, refer to section 5.5 and
5.6.
Содержание HG-AK
Страница 9: ...A 8 MEMO ...
Страница 103: ...5 WIRING OPTION 5 34 MEMO ...
Страница 163: ...6 HG MR SERIES HG KR SERIES 6 60 MEMO ...
Страница 321: ...9 HG RR SERIES 9 12 MEMO ...
Страница 333: ...10 HG UR SERIES 10 12 MEMO ...
Страница 347: ...11 HG AK SERIES 11 14 MEMO ...