2.10
System Configuration
A basic FX PLC system can consist of a stand alone base unit, with the functionality and I/O
range increased by adding extension I/O and special function modules. An overview of available
options is given in sections 2.8 and 2.9.
Base Units
Base units are available with different I/O configurations from 10 to 128 points but can be
expanded to 384 points depending upon the FX range selected.
Extension Boards
Extension adapter boards can be installed directly into the base unit and therefore do not require
any additional installation space. For a small number of I/O (2 to 4) an extension adapter boards
can be installed directly into the FX
1S
or FX
1N
controller. Interface adapter boards can also pro-
vide the FX PLC with additional RS232 or RS485 interfaces.
Extension I/O Modules
With the exception of the FX
1S
series, unpowered modular extension blocks and powered com-
pact extension units modules can be added to all base units of the FX family. For modular exten-
sion blocks powered by the base unit, the power consumption has to be calculated as the 5 V DC
bus can only support a limited number of expansion I/O.
Special Function Modules / Special Adapters
A wide variety of special function modules are available for all FX PLCs, again the exception is
the FX
1S
. They cover networking functionality, analog control, pulse train outputs and tempera-
ture inputs (for further details please refer to section 2.9).
System Configuration
The Hardware
2 - 34
MITSUBISHI ELECTRIC
2
4
-
D
G
R
U
N
B
R
U
N
A
A
2
4
+
FX -16LNK-M
2N
0
MOD
ERR
0
8
1
9
2
A
3
B
ON LINE S
TATION
4
C
5
D
6
E
7
F
1 2 3
OFF
ON
OFF
ON
OFF
ON
ERROR STATION
IN
POWER
0N
-3A
FX
FX base unit
Special function modules
Compact extension unit
Содержание FX2N-32CAN
Страница 1: ...MITSUBISHI ELECTRIC FACTORY AUTOMATION Programmable Logic Controllers GX IEC Developer ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...IV MITSUBISHI ELECTRIC ...
Страница 18: ...Modular PLC Training Hardware Course Overview and Requirements 1 2 MITSUBISHI ELECTRIC ...
Страница 172: ...Monitoring Instances of Function Blocks Advanced Monitoring Functions 7 12 MITSUBISHI ELECTRIC ...
Страница 176: ...Device Edit 8 4 MITSUBISHI ELECTRIC ...
Страница 190: ...Assigning DUT Variables to Function Blocks Data Unit Types DUT 10 10 MITSUBISHI ELECTRIC ...
Страница 198: ...Array Example Single Dimension Array Arrays 11 8 MITSUBISHI ELECTRIC ...
Страница 219: ...Sequential Function Chart SFC SFC Elements Training Manual GX IEC Developer 14 3 ...
Страница 220: ...14 3 SFC configuration examples SFC configuration examples Sequential Function Chart SFC 14 4 MITSUBISHI ELECTRIC ...
Страница 230: ...Structured Text Program Example IEC Structured Text 16 4 MITSUBISHI ELECTRIC ...
Страница 248: ...Configuring GX IEC Developer to access the PLC on Ethernet Ethernet Communications 18 10 MITSUBISHI ELECTRIC ...
Страница 278: ...PLC Components Glossary Appendix A 18 MITSUBISHI ELECTRIC ...
Страница 283: ......