389
For customers who are replacing the conventional model with this inverter
(4) Main differences and compatibilities with the FR-F500(L) series
Appendix 1-2 Replacement of the FR-A100 <EXCELENT> series
Instructions for installation
• When using the installation holes of the FR-A100(E) series, FR-A5AT (intercompatibility attachment) is necessary.
Item
FR-F500(L)
FR-F700
C
h
ang
ed f
un
ct
io
ns
Simple mode
parameters
61 parameters
20 parameters
User group
User group 1 (16), user group 2 (16)
(
Pr. 160, Pr. 173
to
Pr. 175
)
User group (16) only
Setting methods were partially changed
(
Pr. 160, Pr. 172
to
Pr. 173
)
Communication
option
Performing parameter clear and all clear (H5A96,
HAA99) with the FR-A7ND clears
Pr. 345
and
Pr.
346
.
Pr. 345
and
Pr. 346
are not cleared.
Advanced PID
(pump function)
Pr. 500
to
Pr. 516
Parameter number change
Pr. 575
to
Pr. 591
C
ha
nge
d
in
itia
l v
alu
e
Pr. 0 Torque
boost
Initial value
00250 to 00770: 2%, 00930, 01160: 1.5%
(When the torque boost value of the FR-F500 series
used was the initial value, it is not necessary to change
the torque boost value from the initial value when
replacing with the FR-F700 series.)
D
el
e
te
d fu
nc
tio
n
s
User initial
value setting
(
Pr. 199
)
Available
Not available
Substitutable with the copy function of the operation
panel (FR-DU07)
Intelligent
optimum
acceleration/
deceleration
Available
(
Pr. 60
setting "3" and
Pr. 61
to
Pr. 63
)
Not available
For deceleration time, overvoltage fault can be avoided
with regeneration avoidance function (
Pr. 882
to
Pr. 885
).
Automatic
torque boost
Pr. 38
,
Pr. 39
Automatic torque boost was cleared because of addition
of "Simple magnetic flux vector" (
Pr. 80
)
Terminal block
Removable terminal block
Removable terminal block
Upward compatibility (Terminal block of the F500 can be
mounted)
PU
FR-PU04, DU04
FR-PU07
FR-DU07
FR-DU04 unavailable (Partly restricted when the FR-
PU04 is used.
)
Plug-in option
Dedicated plug-in option (not compatible)
Computer link, relay output option
FR-A5NR
Built into the inverter
(RS-485 terminal, relay output 2 points)
Three boards can be mounted
Two board can be mounted
Installation size
FR-F720-00046, 00105, 00167, 00340, 00770, 00930, 01250, 01870, FR-F740-00023 to 00083, 00170,
00470, 00770 to 01160 are compatible in mounting dimensions
For other capacities, an optional intercompatibility attachment (FR-AAT) is necessary.
Содержание 700 Series
Страница 11: ...MEMO ...
Страница 23: ...12 MEMO ...
Страница 341: ...330 MEMO ...
Страница 365: ...354 MEMO ...
Страница 379: ...368 MEMO ...
Страница 397: ...386 MEMO ...
Страница 414: ...403 MEMO ...