308
Useful functions
4.22.6 Initiating a fault (Pr.997)
.... The specification differ according to the manufacture date.
Refer to page 400
and check the SERIAL.
The above parameters can be set when
Pr. 160 User group read selection
= "0".
(Refer to page 190)
(1) Fault initiation
(Pr. 997)
⋅
To initiate a fault, set the assigned number of the fault you want to initiate in
Pr. 997 Fault initiation
.
⋅
The value set in
Pr. 997 Fault initiation
is not stored in EEPROM.
⋅
When a fault occurs, the inverter trips, and the fault is displayed and output (ALM, ALM2).
⋅
While the initiated fault is occurring, the fault is displayed as the latest fault in the faults history. After a reset, the
faults history goes back to the previous status. (The fault generated by the fault initiation function is not saved in the
faults history.)
⋅
Perform inverter reset to cancel the fault.
⋅
Setting for
Pr. 997 Fault initiation
and corresponding faults
* Refer to the FR-F700 PLC function programming manual for details of the PLC function.
A fault is initiated by setting the parameter.
This function is useful to check how the system operates at a fault.
Parameter
number
Name
Initial value
Setting range
Description
997
Fault initiation
9999
16 to 18, 32 to 34, 48, 49,
64, 80 to 82, 96, 112, 128,
129, 144, 145, 160, 161,
162, 164 to 168,
176 to 179, 192 to 194,
196 to 199, 228 to 230,
241, 242, 245 to 247, 253
The setting range is same with the one for
fault data codes of the inverter (which can
be read through communication).
Written data is not stored in EEPROM.
When "0" is set, nothing happens.
9999
The read value is always "9999."
This setting does not initiate a fault.
REMARKS
⋅
If a fault is already occurring in the inverter, a fault cannot be initiated by
Pr. 997
.
⋅
The retry function is invalid for the fault initiated by the fault initiation function.
⋅
If another fault occurs after a fault has been initiated, the fault indication does not change.
The fault is not saved in the faults history either.
Setting (Data code)
Fault
16(H10)
OC1
17(H11)
OC2
18(H12)
OC3
32(H20)
OV1
33(H21)
OV2
34(H22)
OV3
48(H30)
THT
49(H31)
THM
64(H40)
FIN
80(H50)
IPF
81(H51)
UVT
82(H52)
ILF
96(H60)
OLT
112(H70)
BE
128(H80)
GF
129(H81)
LF
144(H90)
OHT
145(H91)
PTC
160(HA0)
OPT
161(HA1)
OP1
162(HA2)
OP2
164(HA4)
E.16*
165(HA5)
E.17*
166(HA6)
E.18*
167(HA7)
E.19*
168(HA8)
E.20*
176(HB0)
PE
177(HB1)
PUE
178(HB2)
RET
179(HB3)
PE2
192(HC0)
CPU
193(HC1)
CTE
Setting (Data code)
Fault
194(HC2)
P24
196(HC4)
CDO
197(HC5)
IOH
198(HC6)
SER
199(HC7)
AIE
228(HE4)
LCI
229(HE5)
PCH
230(HE6)
PID
241(HF1)
E.1
242(HF2)
E.2
245(HF5)
E.5
246(HF6)
E.6
247(HF7)
E.7
253(HFD)
E.13
Setting (Data code)
Fault
Содержание 700 Series
Страница 11: ...MEMO ...
Страница 23: ...12 MEMO ...
Страница 341: ...330 MEMO ...
Страница 365: ...354 MEMO ...
Страница 379: ...368 MEMO ...
Страница 397: ...386 MEMO ...
Страница 414: ...403 MEMO ...