(2) Automatic parameter setting using the operation panel (parameter setting mode)
Operation example
Automatically apply the extended PID display settings in parameters
Pr.999 setting
Description
Operation in the parameter setting mode
2
Extended PID display increment
setting
(AUTO)
→
(PId)
→
Write "2"
10
GOT initial setting (PU connector)
(AUTO)
→
(GOT)
→
Write "1"
20
50Hz rated frequency
(AUTO)
→
(F50)
→
Write "1"
31
Acceleration/deceleration time
(0.01s increment)
(AUTO)
→
(T0.01)
→
Write "1"
are displayed alternately ... Why?
The inverter is not in the PU operation mode.
1.Press .
is lit and the monitor (4-digit LED) displays "0." (When
Pr.79
="0 (initial setting)")
2.Carry out operation from step 3 again.
1.
Screen at powering on The monitor display appears.
PU indication is lit.
2.
Press to choose the PU operation mode.
The parameter
number read
previously appears.
Operation
Display
3.
Press to choose the
parameter setting mode.
4.
Turn until (AUTO)
appears.
5.
Press to enter the automatic
parameter setting mode.
7.
Press to read the present
UGV
value.
" " appears.
6.
Turn until (PID) appears.
Flicker Parameter setting complete!!
9.
Press to set.
Turn to read another parameter.
Press twice to show the next parameter.
Press to show the setting again.
8.
Turn to change it to the set value " ".