Loudness Measurement alarms
Alarm Type
Description
Current
1
loudness error
Active when the
Integrated
text value is outside the range bounded by the upper
and lower deviation for a
set duration
. The alarm clears when the
Integrated
text
value is within the range bounded by the upper and lower deviation for a
clear
duration
.
2
Current dialnorm/expected dialnorm Active if the Current Dialnorm is different from the Expected Dialnorm
Last
3
loudness error
Active when the
Last Integrated
text value is outside the range bounded by the
upper and lower deviation. The alarm clears when the
Last Integrated
text value is
within the range bounded by the upper and lower deviation
Last dialnorm/expected dialnorm
Active if the Last Dialnorm is different from the Expected Dialnorm.
Integrated
Integrated loudness reading in LKFS or LUFS, depending on whether the selected
measurement mode in EdgeVision Configurator is in EBU or A85 mode
Last Integrated
Integrated value at the last segment transition.