Device, Feed, and Stream Alarms
Reading Audio Info Frame Alarms
36
Reading Audio Info Frame Alarms
The alarms in the
Audio
info
frame
sub-folder allow you to display HDMI infoframe
metadata information. This information should match the audio received through the HDMI
input.
Audio coding mode
• 1+1: Ch1, Ch2 (dual mono)
• 1/0: Center
• 2/0: Left - Right
• 3/0: Left - Center - Right
• 2/1: Left - Right - Subwoofer
• 3/1: Left - Center - Right - Subwoofer
• 2/2: Left - Right - Surround Left - Surround Right
• 3/2: Left - Center - Right - Surround Left - Surround Right
Dialnorm
Measured dialnorm value, (average loudness value on current segment)
Range: -1 to -31 dB
Preferred downmix mode
Preferred downmix mode recommended by audio source.
Possible options:
•
Left
total
/
Right
total
•
Left
only
/
Right
only
•
Not
indicated
LFE presence
Indicate if LFE (Low-frequency effect) is present in audio signal
possible choices: yes. no
1. EdgeVision normally receives CM.
AC3 metadata alarms (
Continued
)
Alarm Type
Description