18
COMMISSIONING
Maximum Temperature Setting
Before using the shower the maximum temperature
must be checked to make sure that it is at a
safe level. It has been preset to approximately
41°C at the factory but due to variations in site
conditions the maximum temperature may need
adjustment.
The Temperature Overide is set at approximately
5°C below the Maximum Set Temperature.
Note!
Make sure that the hot water temperature is
at least 55°C and that there is sufficient supply.
For Type 2 installations the maximum blend
temperature is determined by the application,
refer to section:
‘Type 2 Valves - Application’
.
1.
Turn on the shower to the maximum
temperature (i.e. fully anticlockwise) and allow
the temperature to stabilise.
If the temperature is too hot or too cold, adjust
as follows:
2.
Use the slotted end of the multi tool (supplied)
to prise the control lever trim away from the
control lever.
3.
Insert the 2.5 mm hexagon key (supplied)
into the recess in the centre of the cartridge
and engage with the temperature adjusting
screw.
4.
Rotate the hexagon key until the required
maximum temperature is obtained at the
shower. Turn anticlockwise to increase the
temperature, or clockwise to decrease the
temperature (¼ turn = approximately 1°C).
5.
Once the desired maximum blend temperature
has been achieved turn off the shower.
6.
Check that the showering temperature is
correct.
7.
Refit the control lever trim.
Off
Temperature Control:
Warm
On
Flow Control:
Max Set
Temp
Cold
Note!
Due to the inclusion of the 14 L/Min outlet
flow regulator, the reduction in flow at high
pressure will be less significant.
Temperature Overide -
approximately 5°C below
Max Set Temperature.
Mid Flow Overide - Reduces water
flow by up to 30% (dependant on inlet
pressures) and can be overridden by
increasing flow to full.
OPERATION
The Mira Element SLT thermostatic mixer is a
thermostatic shower control with a single control
lever for flow and temperature control.
Note!
You will notice a subtle ‘click’ when both
overriding the flow to full flow and the temperature
to maximum. This feature has been designed to
give subtle user feedback.
The control lever operates in the following
sequence: