2.7. DO NOT twist the individual cable cores of the live and neutral conductors,
as this will prevent them from entering the terminal block.
2.8. DO NOT exert strain on the terminal block.
2.9. DO NOT turn-on the electrical supply until the plumbing has been
completed.
Plumbing and Electrical Schematic Diagram
Figure 3
5
4
7
3
8
2
9
1
Low Pressure
High
Medium
Low
Stop
Temperature
Service
Flow
Mira Advance ATL
Optional Outlet
Double Checkvalve
Double-pole
Isolating Switch
Hose
Retaining
Ring
Mains-fed Cold
Water Supply
Clamp
Bracket
RF2
Handset
Holder
Consumer Unit
Isolating
Valve
2.5. A separate, permanently connected supply must be taken from the consumer
unit to the Mira Advance ATL through a double-pole switch, which has at least
3mm contact separation. The switch can be a ceiling mounted pull-cord type
within the shower room or a wall mounted switch in an adjacent room.
2.6. A 30 mA RCD MUST be fitted. This may be part of the consumer unit or a
separate unit.
Note! The terminal block will not accept cable larger than 16mm