37
Malfunction
Cause
Remedy
Rapid
continuous
cycling of
relays.
Renew flow valve.
Faulty inlet sensor.
Clean turbine.
Debris in flow valve
turbine.
Dry out relay board,
control board and wire
78.
When unit
switched on
service light
flashes and
the flow will
not stop after
STOP button
is pressed.
Wet electronics or faulty
relay board.
"
A
C
B
Turn off the electrical
supply by operating
pull-cord switch, wait
for a few moments
(approximately 10
seconds) for Mira
Advance ATL to reset,
turn on pull-cord switch
and operate Advance
ATL. If problem still
persists then contact
Kohler Mira for advice.
Intermittent
Service light
illumination
during
operation.
or
Any other fault
condition.
"
Abnormal site conditions.
"
Service light
on when flow
selected.
Service light
remains on -
no flow
Faulty inlet sensor.
Renew inlet sensor.
"
Faulty outlet sensor.
"
Renew tank assembly.
Renew inlet sensor.
Faulty inlet sensor.
High flow
rate - low
pressure light
comes on,
unit then
goes to stop.
" "
Debris in flow valve
turbine.
Clean turbine. Check
filter is screwed fully
home.
Poor wire 78 (multi-
connector) connection.
Check integrity of wire
78 connection. Ensure
that the connector is
fully pushed home.
Renew relay board.