1.1. To remove the Mira Advance ATL
case remove the screw at the bottom
of the case.
1.2. Pull the bottom of the Mira Advance
ATL cover outwards and upwards off
the case.
1.3. Slide out the inlet shield, located
over the inlet connector assembly.
1.4. Unscrew the transit sealing caps from
the inlet and outlet of the Mira Advance
ATL.
1.5. When installing the Advance ATL
with concealed water and electrical
supplies refer to, "Dimensions:
Water and cable entry points".
1. Mira Advance ATL
Read Section 2 "Important Safety Information" first.
WARNING! Isolate the electrical and water supplies before proceeding with the
installation of the Mira Advance ATL. The electricity must be turned off at the mains
and the appropriate circuit fuse removed, if applicable.
Note! Bottom inlet is illustrated for clarity in these instructions.
Screw
Wire 78 Multi-
connector
Inlet Shield
Transit
Sealing Cap