47
1.1. Use a screwdriver to remove the
screw from the bottom of the case.
Caution! The cover is connected to
the case by the wire 78 multi-
connector, which should not be
strained when carrying out the next
instruction.
1.2. Pull the bottom of the cover outwards
and upwards off the case.
1.3. The restriction dial is located on the
control PCB, inside the Mira Advance
ATL cover assembly (refer to Figure
9).
1.4. Insert a screwdriver into the slotted
arrow on the restriction dial and rotate
the arrow to the desired number to
set the maximum water temperature
as listed in Table 1.
1.5. Refit the cover by locating the top of
the cover onto the location strip on
the top of the case. Make sure that
the wire 78 multi-connector lead is
seated between the tank body and
the left- hand side of the case and is
pushed fully home.
1.6. Push the bottom of the cover against
the case. Fit the screw and tighten.
Figure 9
WARNING! Isolate the electrical and water supply before removing the cover.
WARNING! Refer to wiring diagram before making any electrical connections.
Advance ATL
Cover
Rotate the arrow on the
'Restriction Dial'
to set the desired
maximum water
temperature
0
1
2
3
4 5
6
7
(viewed from
the back)
Содержание Advance ATL
Страница 48: ...48 SpareParts ...