19
DO NOT connect directly back into
the wall.
1.11. Thoroughly flush the mains-fed
cold water supply pipe. The
supply must be clean and free
from debris BEFORE connecting
the Mira Advance ATL.
Note! Debris will reduce the
performance of the unit.
To flush the pipework, turn on
the water supply and drain a
minimum of 10 litres (2 gallons)
of water into a bucket or
catchment area. Turn off the
water supply.
1.12. Avoiding buried cables and pipes,
choose one of the upper fixing holes
which will allow the Mira Advance
ATL to be firmly fixed to the wall
structure, and drill through the
thinned hole section in the back of
the case.
1.13. Offer the Mira Advance ATL up to
the wall and temporarily connect
the mains-fed cold water supply
pipe. Mark through the casing the
position of the upper and lower holes.
Remove the Mira Advance ATL
from the wall before drilling. This
will prevent debris from entering the
Mira Advance ATL.
1.14. Drill and suitably plug the two fixing
holes. Secure the Mira Advance
ATL to the wall with the screws
provided. Alternative fixings (not
supplied) may be necessary for
some wall structures.
Upper Fixing Holes
INLET
Lower Fixing Holes