24
7.
Press the 'MEDIUM' flow button and observe an increase in flow of water, the
green indicator and the audible tone. Allow the Mira Advance ATL to operate for
2 minutes.
8.
Press the 'HIGH' flow button and observe an increase in flow of water, the green
indicator and the audible tone. Allow the Mira Advance ATL to operate for
2 minutes.
9.
Turn the 'TEMPERATURE' control to cold and then slowly turn the
'TEMPERATURE' control from cold through to position number 6, which is a
typical showering temperature. If a satisfactory temperature cannot be achieved,
then turn the 'TEMPERATURE' control through to position number 8.
12.
Press the 'STOP' button and observe the red indicator and audible tone.
The Mira Advance ATL will continue to run for a few seconds before
shutting off. Audible "clicks" will be heard.
Note! To ensure the commissioning process is memorised by the Mira Advance
ATL the STOP button must be pressed before electrically isolating the Mira
Advance ATL.
Note! Water may continue to drip for a short time whilst the water drains out of
the handset .
Note! High cold water mains supply pressures and high shower temperatures
will cause a slight audible hissing sound to be heard from the Mira Advance ATL
whilst it is operating. This is quite normal and does not indicate that there is a
fault with the Mira Advance ATL.
Note! Changing the temperature requires the
staged power up and power down of individual
heating elements. During this sequence the
user may hear a number of audible 'clicks' from
the relays.
10.
Press the 'MEDIUM' flow button. The flow of
water will decrease, but the selected temperature
will remain relatively constant.
11.
Press the 'LOW' flow button. The flow of water
will decrease, but the selected temperature will
remain relatively constant.
5
4
7
3
8
2
9
1
Low Pressure
High
Medium
Low
Stop
Temperature
Service
Flow