10. Interface specifications
MiR500 User guide (en) 09/2019 - v.1.3 ©Copyright 2018-2020: Mobile Industrial Robots A/S.
141
The GPIO supports low current/power devices like relays, contactors, lamps and/or separate
PLC units.
Figure 10.3. It is intended that outputs and RTNs are used to send signals to the top application, and inputs and
24V pins are used to receive signals from the top application.
The GPIO has the following features:
•
Four inputs, for use with 24V, but robust against 48V.
•
Four outputs, for use with 24V.
To use the GPIO for a top application of your own design, ensure that the
Pallet lift
feature
is disabled. This setting is found under
System > Settings > Features
.