![Minolta EP4000 Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/minolta/ep4000/ep4000_general-mechanical-electrical_1802966069.webp)
Interleaf EP5000/EP4000 GENERAL, MECHANICAL/ELECTRICAL
97.04.01
M-55
(2) Detection of Toner Collecting Box in Position
D
Provided inside the Paper Feed Cabinet (in the copier for EP4000 for the areas oth-
er than the U.S.A., Canada, and Europe) is a Toner Collecting Box Set Sensor. If
no box is installed, the sensor causes a warning message to appear on the Touch
Panel and the initiation of a new copy to be inhibited.
1134M037EA
1134M030AA
Toner
Pipe
Actuator
Toner Collecting Box
Cabinet
(EP4000, except U.S.A., Canada, and Europe)
PC107
Actuator
Toner
Collecting
Box
Pipe
Toner
PWB-A
Toner
Collecting
Box Set
Sensor
Controlled Part
Control Signal
Blocked
Unblocked
WIRING DIAGRAM
PC107
PWB-A PJ19A-9
L
H
21-F