Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
S-31
Tech. Rep. Mode
"
Counter
Touch Panel
Display
Operation
Consumables
Enter the count of the Copy Kit counter. When the count, which is increased
by 1 each time a copy is made, reaches the set count, the maintenance call
reminder message, together with maintenance code “M4,” is displayed.
Note: Whether the maintenance call reminder message is given or not de-
pends on the setting made for “Copy Kit Counter” of “Tech. Rep.
Choice.”
D
Toner collect
Enter the count of the Toner Collect counter. When the count, which increases
by 1 each time a copy is made, reaches the set count, the maintenance code
“M2” is displayed. After wards, the machine stops operating after 10k copies
are made and the maintenance call reminder message is displayed.
Note: The set count should be no more than 200k for U.S.A. areas, 180k for
European areas.
<Setting a Count>
1. Using the
B
or
Y
key, select the counter to be set.
2. Enter the value from the 10-Key Pad.
<Clearing the Set Value/Count>
Using the
B
or
Y
key, highlight the count to be cleared, then press the Clear
key.
Note: If a count is accidentally cleared, pressing the Interrupt key will undo the
clear operation.
<Resetting the Counter>
Using the
B
/
Y
key, select the counter corresponding to the displayed mainte-
nance code, then press the clear key.
Auto CPU Reset
Shows whether a CPU overrun has occurred in different CPU-mounted boards
which are monitored by the watchdog function.
Display
Description
Display
Description
MSC/Panel
PWB-B
ADF
Original System Opt.
Master
PWB-A
Sorter
Exit System Opt.
SCP
PWB-F
Data
Controller
D-102 (PWB-A)
Note: This counter does not count the number of CPU overruns which have
occurred. “1” indicates that there was a CPU overrun, while “0” indi-
cates there was no CPU overrun.
<Clearing the Count>
Using the
B
or
Y
key, highlight the count to be cleared, then press the Clear
key.
Note: If a count is accidentally cleared, pressing the Interrupt key will undo the
clear operation.
Содержание EP4000
Страница 6: ...Interleaf EP5000 EP4000 GENERAL MECHANICAL ELECTRICAL 97 04 01 GENERAL 1151SBG000CA ...
Страница 14: ...Interleaf EP5000 EP4000 GENERAL MECHANICAL ELECTRICAL 97 04 01 MECHANICAL ELECTRICAL 1151SBM000CA ...
Страница 113: ...Interleaf EP5000 EP4000 DIS REASSEMBLY ADJUSTMENT 97 04 01 EP5000 EP4000 DIS REASSEMBLY ADJUSTMENT 1156SBD000AA ...
Страница 271: ...Interleaf EP5000 EP4000 TROUBLESHOOTING 97 04 01 EP5000 EP4000 TROUBLESHOOTING 1156SBT000AA ...