SMART CAT5 SWITCH 16 IP
.
Mouse hotkey
- Used for fast mouse synchronization in Double Mouse mode and
to free the grabbed mouse when in single mouse mode.
Remote Console Button Keys
- Button Keys simulate keystrokes on the remote
system that cannot be generated locally. For example `C Alt + Delete' on
Windows and DOS or `C Backspace' on Linux.
Define a new Button Key as follows:
Type the required keys e.g. Ctrl+Alt+Delete. The + sign means that the keys are
pressed together. The – sign means the keys are pressed sequentially.
The * sign inserts a pause with a definable duration. See page 22.
To require a confirmation request before keystrokes are sent, write
confirm
at the
start. E.g. confirm Ctrl+Alt+Delete.
For a list of key codes and aliases Smart 16 IP recognizes, refer to Appendix B on
page 52.
Press
Apply
for the changes to take effect.
21.
22.
23.
Telnet Console
The Telnet Console offers a Java applet for the Telnet protocol to open a
connection to Smart 16 IP. Its main use is the pass through option for the Serial
port 1 see page 34. The Telnet access has to be enabled in the security settings as
well, see page 40. It is also possible to connect with a standard Telnet client.
For details regarding the Telnet interface please refer to page 47.
Status via IPMI
The Status via IPMI function shows the current values and the min/max-
thresholds of all fans, temperatures and voltages existing in the host system.
Change the thresholds by editing the values and pressing Apply.
The first time you call this page, it can take up to two minutes until the sensor
data appears.
Note: If IPMI is disabled, Status via IPMI and System Log via IPMI are not
available (the menu options are not visible).
Event Log via IPMI
The Event Log via IPMI accesses the SEL (System Event Log) repository and
reads every entry sequentially. The first time you use this function after starting
Smart 16 IP the complete repository has to be read, what may take 1 or 2 minutes.