OPERATING GUIDE
.
After reading all entries, Smart 16 IP displays them with their time, sensor and
description in accordance with the filter settings. You have the choice between
several pre-settings (i.e. last day, last week) or an exact declaration of the start
and the end date.
Once you change the filter settings, click `Update' to update the shown entries. If
the Get sensor names box is checked, all sensor IDs are shown with their
respective names.
The time shown in the log entries is the SEL time, meaning it is independent of
the system time. The SEL time is shown at the top of the log table. Click Clear
Event Log to delete all entries in the SEL repository.
24. Power Control
The appearance of the power control window depends on the power control
option connected to Smart 16 IP and on the currently activated setting (discussed
on page 36). There are three options available: Power control disabled. Internal
power. External power.
Internal power
Once connected enable the internal power option using the
S
erial settings on page
34.
The Power Control panel enables access to the most important external buttons of
your host system. These buttons are the reset and the ATX power button.
The power button represents the ATX power button on your host system. It is
used to switch the power supply on and off. The ATX power button has 2
operation modes: a short press, and a press of about 4 seconds. As shown in
Figure 10 these two modes are supported separately. The 2 operation modes are
explained in the next section.
Figure 10 Internal Power Control
18
.