33
Procedures
Press the
key.
The “ZERO” on load display will flash on and
off, and zero adjustment can be started.
Warning
:
Take care not to apply load
variations due to vibrations and so on.
If load variation is applied, the zero point
will not stabilized, in due course there is a
possibility that correct reading of zero
won’t be obtained.
10
When completed, the display on the load display
will show “SPAN”.
However, when the initial load is not entered the
range of
−
0.3 mV/V to 2.4 mV/V, the right Error
code will be shown for about 2 seconds, then the
display on the load display section will be shown
as “ZERO”, and then the procedure 9 can be
entered.
TE
−
L
:
Zero point
−
OVER
TE
−
H
:
Zero point
+
OVER
Error code
Error code
11
Apply the same load on the load cell as set in the
step 8.