The fieldbus card contains all functions to provide a complete CC-Link slave with transfer
rates up to 10 Mbps.
The CC-Link connection is established by the 5-pin terminal
.
The card is inserted into "Slot 2"
(see Chapter
).
Note:
This fieldbus card does
not
support the "EasyFill" application.
Technical data
Designation
Data
Transfer rate
156; 625 kbps; 2.5; 5, 10 Mbps
Protocol
CC-Link slave
-
CRC error recognition according to IEC 62026 (EN 50325)
-
Max. 64 station nodes
-
128 I/O bits and 16 (32 bit) words
-
Watchdog Timer
(see Chapter
)
Configuration
CSP file "PR1721_1.csp"
Potential isolation
Yes, optocoupler and DC/DC converter
Bus termination
110
Ω
at the cable ends
Bus load
100 mA
Cable type
2x2 screened twisted pair
Cable length
100 m @ 10 Mbps, 1200 m @ 156 kbps
Certificates
-
Type: ABS-CCL (H/W: 1.01, S/W: 2.00.05, CC-Link: 2.0)
-
Reference no. 372
4 Device installation
Transmitter in field housing PR 5230
EN-93
Minebea Intec