Note:
See Chapter "Description of the I/O Area"
Example:
The gross weight should be read.
I/O size = 8 bytes, counted from byte 0–7
7.15.5.3
ProfiNet I/O settings for S7
Requirements:
-
PR 1721/46 ProfiNet I/O is installed.
Card test:
The device display shows the fieldbus card status.
Under
- [HW-Slots] - [Slot 2] all inputs and outputs are displayed.
Procedure:
Note:
Further details can be found in the supplementary application manual "How to
"
(available upon request from [email protected]).
NOTICE
Potential network problems
A unique device name must be assigned for the hardware configuration and
assignment/download.
Note:
See Chapter "Description of the I/O Area"
Example:
The gross weight should be read.
I/O size = 8 bytes, counted from byte 0–7
7.15.5.4
EtherNet-IP settings for Rockwell workstation
Requirements:
-
PR 1721/47 DeviceNet EtherNet-IP is installed.
1.
Establish communication with the PLC (here: SIEMENS S7-300/400 or S7-1500).
2.
Enter the IP address and network mask under
- [Fieldbus parameter] and
confirm.
3.
Add the PR 5230 device to the project and assign the I/O ranges.
4. Assign the instrument name to the PR 5230.
Transmitter in field housing PR 5230
7 Commissioning
Minebea Intec
EN-192