© 2009 MIMAKI ENGINEERING CO.,LTD.
6.5.12
P.2
6.5.12 Encoder PCB Assy
4. Insert a driver through the gap of the damper to loosen the
screws, remove the
encoder PCB assy
together with
L sensor
BKT
, and then release the connector.
5. Remove the
encoder PCB assy
.
6. Reverse the disassembly procedure for reassembly.
L Sensor BKT
Releasing
connector
Encoder PCB Assy
L Sensor BKT
R.1.1
Maintenance Manual > Disassembly and Reassembly > Electrical Parts > Encoder PCB Assy
Model CJV30/TPC Issued 2008.08.04 Revised 2008.09.17 F/W ver. 1.20 Remark
1.1
Содержание CJV30 Series
Страница 315: ......
Страница 316: ...Printed in Japan D500387 13 05112010 2010 MIMAKI ENGINEERING CO LTD IT FW 2 5...