© 2009 MIMAKI ENGINEERING CO.,LTD.
6.2.5
P.1
R.1.0
Maintenance Manual > Disassembly and Reassembly > Ink-related Parts > Pump Assy
Model CJV30/TPC Issued 2008.08.04 Revised
F/W ver. 1.00 Remark
1.0
6.2.5 Pump Assy
Work procedures
1. Remove the
station cover U
.
2. Remove the pump tube connected to the CP coupler.
3. Remove the
pump assy
from the
pump BKT
.
4. Reverse the disassembly procedure for reassembly.
Protrude the pump tube of the discharge side from tube end by 5
to 9 mm.
Pump Assy
Pump Assy
Take care not to pollute the surroundings with waste
ink or washing liquid.