6.2.2 Removing of Head Unit
Work procedures
1. Pull out the
head FFC assy
and
head memory cable assy
from
the
ink slider PCB assy
through the top where the wiring cover
removed.
2. Move the print head carriage onto the platen to make your work
easy.
3. Loosen the screws at two locations on the right and left to
remove the
P cover BKT
.
4. Remove
damper lock SPs
.
Near side: Rotate right and left edges towards you and
remove them.
Rear side: Rotate right and left edges to the rear and remove
them.
5. Place the waste cloth around the head unit so as not to
contaminate the platen.
6. Pull out all
pressure damper SP
assy
s from the print head
carriage and wrap them with the waste cloth so as not to
contaminate their surroundings.
P Cover BKT
Loosen
Damper Lock SP
Wrap with waste cloth.