© 2009 MIMAKI ENGINEERING CO.,LTD.
7.1.3
P.1
R.1.2
Maintenance Manual > Troubleshooting > Details on Errors and Malfunctions > List of Warning Messages
Model CJV30/TPC Issued 2008.08.04 Revised 2009.08.25 F/W ver. 2.00 Remark
1.2
7.1.3 List of Warning Messages
List of Warning Messages (1/3)
No.
Indication on LCD
Cause
Remedy
1
NO MEDIA
No media was detected.
If the warning is displayed again even when the media is set,
check the followings.
1. Check that the R paper sensor functions properly with
[#TEST] -> [SENSOR TEST].
2. Make sure that the cables are connected properly.
3. Replace the media sensor.
2
!EXCHANGE BATTERY
Exhaustion of RTC battery was detected. Replace the battery with a new one having the same model
number.
3
<LOCAL.1>
[#01]
!Replace a WIPER
Time to replace the wiper in the capping
station with a new one has come.
(The wiping count has reached the speci-
fied value.)
Check whether the user replaced the wiper.
([MAINTENANCE] -> [ST.MAINTENANCE])
4
<LOCAL.1>
[#01]
!CONFIRM TEST PRINT
Sleep refresh or cleaning was not per-
formed when power was kept off for 72
hours or more.
Perform TEST DRAW, and check for omitted nozzles.If noz-
zles are omitted, perform cleaning.If nozzle missing is seri-
ous, execute [ST.MAINTENANCE] -> [NOZZLE WASH]
for maintenance.
5
PRE PRT AFT
BREAK
°C
°C
The media heater is disconnected.
(This example shows that preheater is
disconnected.)
1. Check that the media heater functions properly with
[#TEST] -> [HEATER TEST].
2. Make sure that the cables are connected properly.
3. Make sure that fuse of power supply PCB assy is not
blown out.
4. Replace the power supply PCB assy (
) or main
PCB assy (
•The heater PCB assy is for the pre/post heater, and the
power supply PCB assy is for the print heater.
6
PRE PRT AFT
THERM
°C
°C
The thermistor of a media heater is defec-
tive.
(This example shows that the thermistor
of preheater is defective.)
1. Check that the media heater functions properly with
[#TEST] -> [HEATER TEST].
2. Make sure that connection of thermistor is correct.
3. Replace the main PCB assy. (
)
7
<LOCAL.1>
[#01]
NEAR END
MCYK----
Ink for one supply path has been nearly
used up.
Printing is permitted without replacing the ink cartridge (until
INK END is displayed). However, the printer returns to local
mode every completion of printing one file.
8
REMOTE.1
[#01]
NEAR END
MCYK---
9
<LOCAL.1>
[#01]
INK END
----KYCM
Ink for one supply path has been com-
pletely used up.
Replace the cartridge corresponding to the color displayed.
10
REMOTE.1
[#01]
INK END
----KYCM
11
<LOCAL.1>
[#01]
!CARTRIDGE ----KYCM
Ink for one supply path is not yet set, or
unusable ink is being set.
Replace or set the cartridges corresponding to the colors dis-
played.
12
REMOTE.1
[#01]
!CARTRIDGE ----KYCM
13
<LOCAL.1> !CAR [#01]
There is a problem with installed ink car-
tridges.
Displayed only when 4-color cartridges
are installed.
Check the content of the warning by displaying it using the
guidance function.
LOCAL>[ENTER]>[FUNCTION]
14
REMOTE.1
!CAR
[#01]
15
<LOCAL.1> !WSH [#01]
There is a problem with the maintenance
washing liquid. (Displayed only in cut
mode)
•Not set.
•Any cartridge other than that for main-
tenance washing liquid is set.
•The maintenance washing liquid has
been used up.
Replace the maintenance washing liquid cartridge with a new
one.
*REMOTE.1* !WSH [#01]
16
<LOCAL.1> !RTN [#01]
Periodical operation cannot be executed,
since the connection unit is not connected
to the print head.
Start origin setting in print mode, and change the connection
of the connection unit.
Or perform the relevant periodical operation by manual oper-
ation.
*REMOTE.1* !RTN [#01]
17
<LOCAL.1> !TNK [#01]
The waste ink tank is nearly full.
(Displayed only in cut mode)
Replace the waste ink tank with a new one. Execute [MAIN-
TENANCE] -> [InkTankReplace].
*REMOTE.1* !TNK [#01]
Содержание CJV30 Series
Страница 315: ......
Страница 316: ...Printed in Japan D500387 13 05112010 2010 MIMAKI ENGINEERING CO LTD IT FW 2 5...