TROUBLE SHOOTING
Every CompuScale III integrator is subjected to extensive quality assurance procedures to ensure the highest
possible degree of quality, reliability, and performance is achieved.
The following listing indicates the probable cause, and proper course of action to be taken should the
specified fault symptom occur.
SYMPTOM
CAUSE
ACTION
Display blank
» Loss of power
» check power wiring, jumpers, and fuses
» check POWER switch is ON
» check AC supply
» check display board HD2 - 1,4
Will not complete a Zero or
» Loss of input signal(s)
» check P80 - 84 (load)
Span calibration
» check P19 (speed)
» check load sensor wiring
» check speed sensor wiring or constant
speed jumper
» Wrong Design Parameter
» check programming value(s)
Calibration takes too long
» Calibration Duration too long
» reduce P30 value
Zero calibration deviation drifts
» Loose mechanical assembly
» tighten all bolts and clamps
» Material build up on belt
» run belt empty as long as practical
before Zero
Span calibration deviation drifts » Loose mechanical assembly
» tighten all bolts and clamps
Accuracy is not within
» Test Reference doesn’t represent » perform Zero and Span calibration,
desired limits
true operating conditions
followed by a Span Adjust (P8)
» Calibration Duration too low
» increase P30 value *
» Belt Length (P6) incorrect
» enter correct Belt Length (P6)*
» Belt Speed (P4) incorrect
» perform Speed Adjust (P19)
» Load cell signals not
» perform load cell signal
balanced
balance (P90 - P95)*
» Conveyor incline varies
» Install a Milltronics Incline Compensator*
* Perform a new Zero and Span calibration, and a Span Adjust (P8) after the recommended action.
For more trouble shooting information, refer to the belt scale and application guideline instruction manuals.
■