![Milltronics CompuScale III Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/milltronics/compuscale-iii/compuscale-iii_instruction-manual_1796966048.webp)
MAINTENANCE AND SPARE PARTS
MAINTENANCE
The CompuScale III requires no maintenance. However, a program of periodic preventative maintenance
should be initiated. This should include regular inspection, general cleaning and good housekeeping practices.
Enclosures and printed circuit boards should be cleaned only when the power is disconnected at the main
breaker. The use of a vacuum cleaner to remove foreign material dislodged with a clean dry paint brush is
recommended. Check all electrical connections for signs of corrosion and/or electrical arcing.
The CompuScale III memory backup and calibrator batteries should be replaced annually. The 3.6 Volt lithium
battery (located on the mother board top right corner) should only be replaced while the CompuScale III power
is
ON
. The 9 Volt calibrator battery is located on the back of the CompuScale III door.
SPARE PARTS
The following list describes the CompuScale III components which may be ordered as a spare part. The ITEM
# refers to the number which should be included on the purchase order to identify the part required.
DESCRIPTION
ITEM #
Battery, Lithium, 3.6 V, AA, (Memory)
20200031
Battery, Alkaline, 9 Volt, (Calibrator)
20200025
Enclosure Bottom Plate
24650116
Fuse, 0.25A, 250V, Slo-Blo, CSA, (Speed Sensor)
22550070
Fuse, 0.75A, 250V, Slo-Blo, CSA, (Main)
22550112
For other spare part ordering information, contact Milltronics or your distributor.
Pl-367