PROGRAMMING
GENERAL
Information specific to a particular application is entered into the CompuScale III memory, via the keypad,
prior to the calibration procedure.
KEYPAD
Button
Operation
Function
parameter entry
numeric entries
parameter entry
increase: analog mA output (P17 and P18 only), ECAL value (P22 only)
parameter entry
decrease: analog mA output (P17 and P18 only), ECAL value (P22 only)
parameter entry
decimal point
parameter entry
negative entry or display previous parameter
any mode
enter the run mode, return to previously selected display
any mode
enter the program mode, access parameter for entry or viewing
any mode
access zero calibration, view current zero count
any mode
access span calibration, view current span count
any mode
enter the run mode, select rate, total, load, or speed display
any mode
enables a Total display reset (refer to Start Up\Hardware
Set Up\Totalizer Reset)
parameter entry
clear display
calibrate mode
abort calibration
parameter entry
display parameter value, or store altered parameter value,
or display next parameter
calibrate mode
activate zero or span calibration, or accept calibration results
any mode
with total displayed, switch to alternate total (main or sub)
8
0
–
9
RUN
PAR
ZERO
SPAN
ALT
DISP
RESET
TOTAL
CLEAR
ENTER
4
PL-367
5 – 1