ALTERING PARAMETER VALUES
Once the desired parameter number is accessed, the parameter value may be accepted or altered as
required.
e.g.
if the VALUE field of PARAMETER 0 is 1 (T/h), however 2 (LT/h) is desired
[ 2
]
is displayed in the value field
the new value (2) is now stored in memory
LAST PARAMETER RECALL
From the Calibrate or Run mode, the last parameter accessed in the Program mode, may be recalled.
the last parameter accessed is displayed.
PARAMETER RESET
To reset parameters to factory settings, refer to PARAMETERS/P99 Reset.
PROGRAMMING SEQUENCE
Typically, the CompuScale III is programmed as follows:
a) Referring to the Belt Scale Design Summary and PARAMETERS section, copy the appropriate
parameter values to the spaces provided on the PROGRAMMING CHART fold out.
b) Perform a MASTER RESET (P99).
c)
Access each parameter in sequence from P0 and enter the
parameter values from the PROGRAMMING CHART.
d) Perform a Zero and Span calibration (refer to CALIBRATION)
e) Perform Span Adjust (P8), or Factoring (P9), and Speed Adjust (P19) procedures, as required.
Remember to copy any parameter value alterations onto the
PROGRAMMING CHART for future reference.
QUICK START GUIDE
A Quick Start Guide is shipped in the CompuScale III integrator enclosure. This guide describes the minimum
start up, programming, and calibration requirements of the CompuScale III, to obtain successful RUN mode
operation for most applications.
If desired, follow the Quick Start Guide procedure. Parameters which are not included in the guide may be
programmed after the RUN mode is entered.
■
ENTER
2
ENTER
PAR