OM-2240 Page 50
B. LockOut Levels
NOTE: Before activating lock out
levels, be sure that all procedures
and parameters are established.
Parameter adjustment is limited
while lock out levels are active.
Level 1
NOTE: Remote amperage control
is not available in level 1.
TIG Output Selection
If either the TIG HF Impulse or TIG
Lift Arc process (see Section 5-7)
was active when lockout level 1
was activated, the operator can
choose between RMT STD (Re-
mote Standard) or RMT 2T HOLD
(Remote 2T Hold). The On function
is also available if TIG Lift Arc was
active.
If RMT 2T HOLD was reconfigured
(see Section 6-2C) prior to lockout
level 1 activation, the reconfigured
output mode (4T, 4T momentary,
mini logic, or spot) is available to
the operator instead of RMT 2T.
Stick Output Selection
If the Stick process was active
when lockout level 1 was activated,
the operator can choose between
RMT STD or On.
When parameter change or selec-
tion is limited by lock level 1, [
L-1
] is
displayed as a reminder.
Level 2
NOTE: Remote amperage control
is not available in level 2.
Includes all the functions of level 1
plus Polarity and Process Selection
(see Sections 5-6 and 5-7).
When parameter change or selec-
tion is limited by lock level 2, [
L-2
] is
displayed as a reminder.
For The Stick Process
Process Selection
Level 1
Level 2
Use Output Switch Pad To
Select A Trigger Method
For The TIG Process
Select Process
Use Output Switch Pad To
Select A Trigger Method