This product meets and exceeds the requirements of UL 325, the standard which regulates gate opener safety, 

as established and made effective March 1, 2000, by Underwriters Laboratories Inc.

WARNING!

This equipment is similar to other gate or door equipment and meets or exceeds 
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has 
hazards associated with its use and therefore by installing this product the installer 
and user accept full responsibility for following and noting the installation and 
safety instructions. Failure to follow installation and safety instructions can result 
in hazards developing due to improper assembly. You agree to properly install this 
product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, 
indirect, incidental, special or consequential damages or loss of profits whether 
based in contract tort or any other legal theory during the course of the warranty 
or at any time thereafter. The installer and/or user agree to assume responsibility 
for all liability and use of this product releasing GTO, Inc. from any and all liability.  
If you are not in agreement with this disclaimer or do not feel capable of properly 
following all installation and safety instructions you may return this product for full 
replacement value.

READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to 
install and use this automatic gate opener. This gate opener produces a high level 
of force.  Stay clear of the unit while it is operating and exercise caution at all times.

All automatic gate openers are intended for use on vehicular gates only.

GTO Sales: (800) 543-GATE (4283) or (850) 575-0176 • Fax (850) 575-8912 or

GTO Technical Service (800) 543-1236 or (850) 575-4144

For 24 hour/day, 7 day/week Technical Service visit  http://support.gtoinc.com/support/troubleshooter.aspx

UL325 SERIES 

200

® 

E-Z GATE OPENER 

For more information on Mighty Mule’s full line of Automatic Gate Openers and Access Controls visit our website at www.mightymule.com

Содержание 200 E-Z GATE OPENER UL325 SERIES

Страница 1: ...act tort or any other legal theory during the course of the warranty or at any time thereafter The installer and or user agree to assume responsibility for all liability and use of this product releas...

Страница 2: ...s intended for use with vehicular swing gates The opener can be used in Class I Class II and Class III applications FOR YOUR RECORDS Please record the product serial number located on the rear of open...

Страница 3: ...13 Mounting the Opener page 17 Installation of the Closed Position Stop page 17 Mounting the Control Box page 18 Powering Options Transformer or Solar page 19 Solar Panel and Gate Activity Chart page...

Страница 4: ...ontrol products These optional accessories see the enclosed Mighty Mule Accessory Catalog are available at most stores Your store should be able to special order any accessory not in stock If your sto...

Страница 5: ...mage to the opener or its components serious injury or death Because GTO automatic gate openers are only part of the total gate operating system it is the responsibility of the consumer to ensure that...

Страница 6: ...ify this opener is proper for the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or...

Страница 7: ...hands could be pinched 3 Devices such as contact sensors safety edges and non contact sensors photo beams provide additional protection against entrapment 4 If push buttons or key switches are install...

Страница 8: ...g any maintenance Regularly grease the gate hinges Clean the push pull tube with a soft dry cloth and apply silicone spray to it at least once per month 7 To operate this equipment safely YOU must kno...

Страница 9: ...st entrapment The Mighty Mule utilizes Type A an inherent i e built in entrapment sensing system as the primary type of entrapment protection Also the Mighty Mule has provisions for the connection of...

Страница 10: ...r details Warning signs alert people of automatic gate operation and are required when installing the Mighty Mule E Z Gate Opener Furthermore a walk through gate must be installed if pedestrian traffi...

Страница 11: ...KEEP CLEAR Gate may move at any time 2 Do not allow children to operate gate or play in gate area 3 This gate is for vehicles only Pedestrians must use separate entrance Maximum Gate 300 lbs 249 4 kg...

Страница 12: ...e Bag Contents Gate Opener 1 Installation DVD 1 Gate Bracket 1 Post Pivot Bracket 1 3 8 Bushings 1 Customer Support Card 1 Post Bracket 1 Closed Position Stop Plate 1 2 Mounting Screw 3 Transformer 1...

Страница 13: ...d the Accessory Catalog If your gate is more than 1000 away from AC power source you will need to use at least one Mighty Mule 5 watt Solar Panel FM121 not included to charge the 12 Volt automotive or...

Страница 14: ...er code GTO RF receiver tuned to 318 MHz Opener length with push pull tube fully retracted is 263 8 mounting point to mounting point Maximum stroke is 13 Adjustable auto close timer OFF to 120 s and o...

Страница 15: ...water The addition of a horizontal or vertical cross member if one is not already in place to provide a stable area for mounting the gate bracket is also important Horizontal Cross Member Gate Swings...

Страница 16: ...Overview continued If the gate post is larger than 6 inches the Post Pivot Bracket can be removed and the center hole of the Post Bracket can be the mounting point for the gate opener If installing o...

Страница 17: ...than 6 in diameter or 6 square should be made of metal instead of wood so that it will remain stable while the opener is moving the gate Post Bracket Post Pivot Bracket Metal Plate Wooden Post Post B...

Страница 18: ...the end of the bolt DO NOT overtighten the lock nut because the post pivot bracket will have to be adjusted later Step 2 Attach post bracket assembly to the rear mount of the opener with a clevis pin...

Страница 19: ...achieve these important clearances and distance With the post pivot bracket in the optimum position for clearance and freedom of movement reattach the opener to the gate bracket in the open position...

Страница 20: ...r than 8 not supplied must be used Step 8 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots Drill 3 8 holes into the gate cross member as marked Mount...

Страница 21: ...izontal cross member Post Bracket Assembly bolted to fence post Clevis Pin Bushing and Hairpin Clip Clevis Pin Washer and Hairpin Clip Gate Bracket bolted to gate cross member Fence Post Step 10 Remov...

Страница 22: ...transmitter range The top of the fence is an acceptable location for mounting the control box If necessary attach a backing piece of wood when mounting the control box to a metal fence Leave enough sl...

Страница 23: ...weatherproof cover or housing available at local electrical supply stores must be used If your gate is more than 1000 ft from an ac power source you will need to use at least one 5 watt Solar Panel to...

Страница 24: ...and the BLACK wire to the COM terminal on the control board as shown Tighten set screws against exposed end of wires A dab of household petroleum jelly on each terminal will help prevent corrosion NOT...

Страница 25: ...R OFF 120 AUTO CLOSE T ME MIN MAX STALL FORCE ON OFF SG1 ED1 K1 06 AVR SP D1 C2 C7 C15 LED3 D15 R20 IC4 D16 D13 D14 K2 BATT BATT STATUS ANT SHLD S9 8874 EDGE COM LOCK LOCK PGOK200 Rev XC M_BLK M_RED V...

Страница 26: ...uit to reach the control box IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE The only wire acceptable for use with GTO products is 16 gauge multi stranded low voltage PVC sheathed wire This particular ga...

Страница 27: ...sed wires do not touch each other Step 5 Strip 3 16 off the ends of the low voltage wire and twist tightly Attach these ends to the CHGR terminals located on the terminal block see illustration at rig...

Страница 28: ...d position of the gate Make sure the last running state is in the closing direction The gate is now at the desired closed position limit Step 4 Press hold the transmitter to run the gate open uninterr...

Страница 29: ...r approximately two 2 seconds Use a small slotted screwdriver to turn the arrow in the center of the potentiometer Adjust the sensitivity from the MINIMUM position where the gate operates without obst...

Страница 30: ...a small screwdriver to move the switches All GTO transmitters are set to a standard code at the factory and are ready to operate your Mighty Mule Gate Opener For your safety and security however we s...

Страница 31: ...es Call GTO Sales at 1 800 543 4283 for information on compatible products for your specific application Make sure the power to the opener is turned off before connecting safety device wiring to the t...

Страница 32: ...put while at open limit will restart the auto close time if enabled 5 CYCLE Typically for use with doorbell button or hardwired keypad Each activation at this input will cycle the operation as follows...

Страница 33: ...Refer to Vehicle Sensor manual for additional information if needed Edge Sensor GTO Lock ON 1 2 3 4 5 6 7 8 9 10 D P NO COM NC V V LOOP LOOP LOOP NOTE Connections are for typical applications For addi...

Страница 34: ...encountered two 2 obstructions without reaching either limit Power cycle to reset the alarm Transmitter will not operate the gate Alarm will automatically shut off after 5 minutes d 1 beep every 20 s...

Страница 35: ...of the mounting brackets and readjust if necessary 2 Check the gate for binding or hinge damage 3 Adjust stall force if necessary VOLTAGE RATINGS 18 Vac Transformer__________________________18 0 to 22...

Страница 36: ...r issued to you on the outside of the package in LARGE BOLD PRINT and include a copy of the receipt for proof of purchase Ship the package s freight prepaid to GTO Inc 3121 Hartsfield Road Tallahassee...

Страница 37: ...instead of pulling it toward the column It is recommended that you place a steel plate between the opener mounting brackets and masonry surface for additional strength B If a push to open installatio...

Страница 38: ...systems battery is included Digital Keypad FM137 The specially designed digital keypad can be easily installed as a wireless or wired keypad It can be programmed to use up to 25 different personal ide...

Страница 39: ...te operator and your garage door operator Compatible with most garage door operators Wireless Entry Intercom Keypad FM136 Allows owner to screen guest at the gate before allowing access to the propert...

Отзывы: