24
M i g h t y M u l e 2 0 0
Fully Open Position
Fully Closed Position
Your Mighty Mule 200 has two Limit Settings
1.
OPEN Limit setting:
(Gate in the OPEN POSITION / FACTORY SET &
NOT ADJUSTABLE) The open limit setting is the fully open position.
2.
CLOSED Limit setting:
The CLOSED Limit setting (gate in the
CLOSED POSITION) To achieve optimum closed position, you are
required to complete the following FIVE STEPS:
Step 1
With the gate in the fully open position (arm fully retracted), slide the ON/OFF switch on the control box
to the OFF position.
If gate is not open, use the transmitter to put the gate into the fully open position,
then slide the ON/OFF switch on the control box to the OFF position.
Step 2
Press and hold the hand held transmitter button while sliding the ON/OFF switch to the ON position.
Continue to hold the transmitter’s button until the alarm sounds (3-5 seconds). The unit is now in the
‘LEARN LIMIT’ mode. (
In this mode the unit will run only when the transmitter is held down.
The
gate will stop when the transmitter’s button is released. The gate will alternate its running direction each
time the button is pressed.)
Step 3
Press and hold the transmitter’s button to close the gate. Prepare to release the transmitter’s button
when the gate reaches the desired closed position. (Note: Use the transmitter to ‘fine-tune’ the closed
position of the gate. Make sure the last running state is in the closing direction). The gate is now at the
desired closed position limit.
Step 4
Press & hold the transmitter to run the gate open
uninterrupted
all the way to the full open limit. If the
gate stops prior to reaching the open limit position,
bring the gate back to the desired closed position
and repeat steps 2 and 3. (Note: If the gate stops and
reverses while the transmitter is held down, the ‘STALL
FORCE’ adjustment may be set too low. Turn ‘STALL
FORCE’ pot clockwise and repeat steps 2-3)
Step 5
Once the gate reaches the open position limit you
will hear a single beep from the alarm confirming
that the closed position limit is ‘learned’. The unit will
automatically exit ‘LEARN LIMIT’ mode and return to
normal operation (momentary press of the transmitter
will operate the gate). Run the gate to the closed
position and verify that it stops at the desired position.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gate to close.
If CLOSED position is not correct or needs to be changed you
will need to repeat steps 1-5.
Setting the Closed Position Limit
POWER
O
MIN
MAX
STALL
FORCE
ON OFF
SG1
K1
06
AVR-ISP
D1
C2
C7
C15
LED3
D15
R20
C4
D16
D13
D14
K2
BATT BATT+
EDGE
COM
LOCK+
LOCK -
PGOK200 Rev. XC
M_BLK
M_RED
VAR2
GRN
VAR3
AR3
VAR1
AR4
VAR5
PF1
VAR6
WHT
GTO Inc. Tallahassee, FL
CYCLE
EXIT
SAFETY
COM
CHGR
CHGR
ON/OFF SWITCH
STALL FORCE
Note:
Must have a transmitter that operates the gate. If not see 'Setting Your
Personal Transmitter Code' on page 26.