background image

If you have a question about any special order item, 

just call 1-800-543-GATE!

Accessories are Available From Your Retail Store (con't)

The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be 
reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO.  Any reprinting of GTO publications is by 

permission only. Copyright infringement is a violation of federal law. 

 

Mighty Mule¨, E-Z Gate¨, GTO¨, are registered trademarks of GTO, Inc.  America’s DIY Automatic Gate Openers is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc. 

(“GTO”).  

All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.  

Replacement Transformer (RB570)

Standard 18 volt, 2200 mA, AC transformer for maintaining the battery included with the 

Mighty Mule® 

gate operator. This is the only transformer approved for use with 

all UL325 Mighty Mule® 

gate operator 

systems.

Garage Door Receiver (RB709U-NB) 

The Garage Door Receiver allows you to use the same 

Mighty Mule® 

entry transmitter to operate your 

gate operator and your garage door operator. Compatible with most garage door operators.

Wireless Entry Intercom / Keypad (FM136)

Allows owner to screen guest at the gate before allowing access to the property. Keypad also allows 

owner to give up to 25 programmable entry codes to family, friends or approved delivery personnel. 

Codes can be permanent or temporary. Can be wireless up to 500 feet.

Additional base stations available (F3101MBC).

Driveway Alarm (FM131)

Keep track of the comings and goings on your property with this electromagnetic sensor alert 

system. When a vehicle passes the sensor, the receiver emits an audible tone and lets you know 

someone’s there. Functional range of up to 400 ft. Easy-to-install and stake is included in kit.  

Transmitter requires 2 “C” batteries (not included)

Wireless Driveway Vehicle Sensor (FM130)

The wireless gate opening sensor offers hands free operation of the Mighty Mule Gate Opener. Works 

wirelessly up to 100 feet from the gate. Transmitter, receiver and two AA batteries are included. 

Low Voltage Wire (RB509) 

The 16 gauge, multi-stranded, dual conductor 

Low Voltage Wire

 is for connecting  the AC powered  

transformer, or the 

Solar Panel 

to the control board. Also used for the connection of accessories, 

such as locks, keypads, push buttons and other wired  control devices. This specially designed wire 

is UV treated, PVC coated and ready for direct burial. Available in 1000' rolls or special lengths.

Содержание 200 E-Z GATE OPENER UL325 SERIES

Страница 1: ...act tort or any other legal theory during the course of the warranty or at any time thereafter The installer and or user agree to assume responsibility for all liability and use of this product releas...

Страница 2: ...s intended for use with vehicular swing gates The opener can be used in Class I Class II and Class III applications FOR YOUR RECORDS Please record the product serial number located on the rear of open...

Страница 3: ...13 Mounting the Opener page 17 Installation of the Closed Position Stop page 17 Mounting the Control Box page 18 Powering Options Transformer or Solar page 19 Solar Panel and Gate Activity Chart page...

Страница 4: ...ontrol products These optional accessories see the enclosed Mighty Mule Accessory Catalog are available at most stores Your store should be able to special order any accessory not in stock If your sto...

Страница 5: ...mage to the opener or its components serious injury or death Because GTO automatic gate openers are only part of the total gate operating system it is the responsibility of the consumer to ensure that...

Страница 6: ...ify this opener is proper for the type and size of gate its frequency of use and the proper class rating 2 Make sure the gate has been properly installed and swings freely in both directions Repair or...

Страница 7: ...hands could be pinched 3 Devices such as contact sensors safety edges and non contact sensors photo beams provide additional protection against entrapment 4 If push buttons or key switches are install...

Страница 8: ...g any maintenance Regularly grease the gate hinges Clean the push pull tube with a soft dry cloth and apply silicone spray to it at least once per month 7 To operate this equipment safely YOU must kno...

Страница 9: ...st entrapment The Mighty Mule utilizes Type A an inherent i e built in entrapment sensing system as the primary type of entrapment protection Also the Mighty Mule has provisions for the connection of...

Страница 10: ...r details Warning signs alert people of automatic gate operation and are required when installing the Mighty Mule E Z Gate Opener Furthermore a walk through gate must be installed if pedestrian traffi...

Страница 11: ...KEEP CLEAR Gate may move at any time 2 Do not allow children to operate gate or play in gate area 3 This gate is for vehicles only Pedestrians must use separate entrance Maximum Gate 300 lbs 249 4 kg...

Страница 12: ...e Bag Contents Gate Opener 1 Installation DVD 1 Gate Bracket 1 Post Pivot Bracket 1 3 8 Bushings 1 Customer Support Card 1 Post Bracket 1 Closed Position Stop Plate 1 2 Mounting Screw 3 Transformer 1...

Страница 13: ...d the Accessory Catalog If your gate is more than 1000 away from AC power source you will need to use at least one Mighty Mule 5 watt Solar Panel FM121 not included to charge the 12 Volt automotive or...

Страница 14: ...er code GTO RF receiver tuned to 318 MHz Opener length with push pull tube fully retracted is 263 8 mounting point to mounting point Maximum stroke is 13 Adjustable auto close timer OFF to 120 s and o...

Страница 15: ...water The addition of a horizontal or vertical cross member if one is not already in place to provide a stable area for mounting the gate bracket is also important Horizontal Cross Member Gate Swings...

Страница 16: ...Overview continued If the gate post is larger than 6 inches the Post Pivot Bracket can be removed and the center hole of the Post Bracket can be the mounting point for the gate opener If installing o...

Страница 17: ...than 6 in diameter or 6 square should be made of metal instead of wood so that it will remain stable while the opener is moving the gate Post Bracket Post Pivot Bracket Metal Plate Wooden Post Post B...

Страница 18: ...the end of the bolt DO NOT overtighten the lock nut because the post pivot bracket will have to be adjusted later Step 2 Attach post bracket assembly to the rear mount of the opener with a clevis pin...

Страница 19: ...achieve these important clearances and distance With the post pivot bracket in the optimum position for clearance and freedom of movement reattach the opener to the gate bracket in the open position...

Страница 20: ...r than 8 not supplied must be used Step 8 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots Drill 3 8 holes into the gate cross member as marked Mount...

Страница 21: ...izontal cross member Post Bracket Assembly bolted to fence post Clevis Pin Bushing and Hairpin Clip Clevis Pin Washer and Hairpin Clip Gate Bracket bolted to gate cross member Fence Post Step 10 Remov...

Страница 22: ...transmitter range The top of the fence is an acceptable location for mounting the control box If necessary attach a backing piece of wood when mounting the control box to a metal fence Leave enough sl...

Страница 23: ...weatherproof cover or housing available at local electrical supply stores must be used If your gate is more than 1000 ft from an ac power source you will need to use at least one 5 watt Solar Panel to...

Страница 24: ...and the BLACK wire to the COM terminal on the control board as shown Tighten set screws against exposed end of wires A dab of household petroleum jelly on each terminal will help prevent corrosion NOT...

Страница 25: ...R OFF 120 AUTO CLOSE T ME MIN MAX STALL FORCE ON OFF SG1 ED1 K1 06 AVR SP D1 C2 C7 C15 LED3 D15 R20 IC4 D16 D13 D14 K2 BATT BATT STATUS ANT SHLD S9 8874 EDGE COM LOCK LOCK PGOK200 Rev XC M_BLK M_RED V...

Страница 26: ...uit to reach the control box IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE The only wire acceptable for use with GTO products is 16 gauge multi stranded low voltage PVC sheathed wire This particular ga...

Страница 27: ...sed wires do not touch each other Step 5 Strip 3 16 off the ends of the low voltage wire and twist tightly Attach these ends to the CHGR terminals located on the terminal block see illustration at rig...

Страница 28: ...d position of the gate Make sure the last running state is in the closing direction The gate is now at the desired closed position limit Step 4 Press hold the transmitter to run the gate open uninterr...

Страница 29: ...r approximately two 2 seconds Use a small slotted screwdriver to turn the arrow in the center of the potentiometer Adjust the sensitivity from the MINIMUM position where the gate operates without obst...

Страница 30: ...a small screwdriver to move the switches All GTO transmitters are set to a standard code at the factory and are ready to operate your Mighty Mule Gate Opener For your safety and security however we s...

Страница 31: ...es Call GTO Sales at 1 800 543 4283 for information on compatible products for your specific application Make sure the power to the opener is turned off before connecting safety device wiring to the t...

Страница 32: ...put while at open limit will restart the auto close time if enabled 5 CYCLE Typically for use with doorbell button or hardwired keypad Each activation at this input will cycle the operation as follows...

Страница 33: ...Refer to Vehicle Sensor manual for additional information if needed Edge Sensor GTO Lock ON 1 2 3 4 5 6 7 8 9 10 D P NO COM NC V V LOOP LOOP LOOP NOTE Connections are for typical applications For addi...

Страница 34: ...encountered two 2 obstructions without reaching either limit Power cycle to reset the alarm Transmitter will not operate the gate Alarm will automatically shut off after 5 minutes d 1 beep every 20 s...

Страница 35: ...of the mounting brackets and readjust if necessary 2 Check the gate for binding or hinge damage 3 Adjust stall force if necessary VOLTAGE RATINGS 18 Vac Transformer__________________________18 0 to 22...

Страница 36: ...r issued to you on the outside of the package in LARGE BOLD PRINT and include a copy of the receipt for proof of purchase Ship the package s freight prepaid to GTO Inc 3121 Hartsfield Road Tallahassee...

Страница 37: ...instead of pulling it toward the column It is recommended that you place a steel plate between the opener mounting brackets and masonry surface for additional strength B If a push to open installatio...

Страница 38: ...systems battery is included Digital Keypad FM137 The specially designed digital keypad can be easily installed as a wireless or wired keypad It can be programmed to use up to 25 different personal ide...

Страница 39: ...te operator and your garage door operator Compatible with most garage door operators Wireless Entry Intercom Keypad FM136 Allows owner to screen guest at the gate before allowing access to the propert...

Отзывы: